8*6mm Gas Discharge Tube for Lightning Protection 75V -3600V Gdt

Product Details
Type: Gas Discharge Tube
Cooling System: Natural
Function: Over Voltage Protection
Still deciding? Get samples of US$ 0/Piece
Request Sample
Gold Member Since 2007

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
42
Year of Establishment
2002-04-27
  • 8*6mm Gas Discharge Tube for Lightning Protection 75V -3600V Gdt
  • 8*6mm Gas Discharge Tube for Lightning Protection 75V -3600V Gdt
  • 8*6mm Gas Discharge Tube for Lightning Protection 75V -3600V Gdt
  • 8*6mm Gas Discharge Tube for Lightning Protection 75V -3600V Gdt
  • 8*6mm Gas Discharge Tube for Lightning Protection 75V -3600V Gdt
  • 8*6mm Gas Discharge Tube for Lightning Protection 75V -3600V Gdt
Find Similar Products
  • Overview
  • Detailed Photos
  • Packaging & Shipping
  • Company Profile
  • Certifications
  • Our Advantages
  • After Sales Service
  • Contact us
Overview

Basic Info.

Model NO.
ZM86 2R 230L
Materials
Ceramic
Size
8*6mm
Impulse Discharge Current
20ka
Impulse Discharge Current 8/20us(Ka) 10
20
Transport Package
100PCS/Box, 5000PCS/Carton
Specification
8*6mm
Trademark
ZM
Origin
Ningbo
HS Code
8536300000
Production Capacity
60, 0000PCS/Month

Product Description

Type(have no lead wire) Ф8×6mm ZM86
2R-75
ZM86
2R-90
ZM86
2R-150
ZM86
2R-230
ZM86
2R-250
ZM86
2R-350
ZM86
2R-500
ZM86
2R-600
ZM86
2R-800
Type(have lead wire)   Ф8×6mm ZM86
2R-75L
ZM86
2R-90L
ZM86
2R-150L
ZM86
2R-230L
ZM86
2R-250L
ZM86
2R-350L
ZM86
2R-500L
ZM86
2R-600L
ZM86
2R-800L
Nominal DC Spark-over voltage 100V/s(V) 75 90 150 230 250 350 500 600 800
Deviation of VS (V)% ±25 ±20 ±20 ±20 ±20 ±20 ±20 ±20 ±20
Impulse spark-over voltage100V/μs(V)  ≤500 ≤500  ≤500  ≤600  ≤600  ≤800  ≤1100  ≤1200 ≤1400 
Impulse spark-over voltage 1KV/μs(V) ≤600 ≤600 ≤650 ≤700 ≤750 ≤900 ≤1200 ≤1300 ≤1600
Impulse dischargecurrent10/350μs(KA)1times  4 4 4 4 4 4 4 4 4
Impulse discharge current 8/20μs(KA) 10times 20 20 20 20 20 20 20 20 15
Impulse discharge current 10/1000μs(A/times) 200/300 200/300 200/300 200/300 200/300 200/300 200/300 200/300 200/300
Alternating discharge current 50Hz 10times(A) 20 20 20 20 20 20 20 20 20
Insulation resistance (Ω) ≥108 ≥108 ≥109 >109 >109 >109 >109 >109 >109
Capacitance (1 MHz) pF <1.3 <1.3 <1.3 <1.3 <1.3 <1.3 <1.3 <1.3 <1.3

Detailed Photos

8*6mm Gas Discharge Tube for Lightning Protection 75V -3600V Gdt
8*6mm Gas Discharge Tube for Lightning Protection 75V -3600V Gdt

Packaging & Shipping

8*6mm Gas Discharge Tube for Lightning Protection 75V -3600V Gdt
8*6mm Gas Discharge Tube for Lightning Protection 75V -3600V Gdt

Company Profile

8*6mm Gas Discharge Tube for Lightning Protection 75V -3600V Gdt

8*6mm Gas Discharge Tube for Lightning Protection 75V -3600V Gdt
8*6mm Gas Discharge Tube for Lightning Protection 75V -3600V Gdt
 

Certifications

8*6mm Gas Discharge Tube for Lightning Protection 75V -3600V Gdt

Our Advantages

Ningbo Zhengmao Electronics Co., Ltd

    With convenient transportation and rapid economical development, Ningbo Zhengmao Electronics Co., Ltd. (with a former name Ningbo Shitong Telecommunication Component Factory) is located in the south of Ningbo Zhejiang Province, ChinaFounded in 2002, our company specializes in researching and manufacturing Switching Spark Gaps, Gas Discharge Tube and others
    Switching Spark Gap (SSG) has voltage mainly ranging from 110V to 800V with many advantages including complete varieties, good stability and long lifetime (it can be switched for over thousands of times to millions of times). This product is mainly used for ignition on HID ballast or street lamps, ect.
    Gas Discharge Tube is anti-aging with high insulation resistance, small capacitance and quick respond. It is widely used for over-voltage protection of telecom and other electronics as well as lightning protection.
    We are a member under identification of Quality Management System (ISO9001-2008QMS). Our products all meet the International standard of IEC61643-311, Recommendation Standard of ITU-T K.12 and the national standard GB/T9043-2008Communication Equipment Over-voltage Protection with General Technical Conditions on Gas Discharge Tube, etc.Gas Discharge Tube has got the TüV certification of German and SGS certification, meeting the rules of RoHS.  
    Based on Quality, we aim at satisfying our customers by continually improving our product quality and service to meet your needs. 

After Sales Service

8*6mm Gas Discharge Tube for Lightning Protection 75V -3600V Gdt
We will do our best to help you solve the problem and hope to receive your valuable opinions and feedback so that we can further improve the quality of our products and services.
Your support is the driving force behind our progress

Contact us

8*6mm Gas Discharge Tube for Lightning Protection 75V -3600V Gdt

8*6mm Gas Discharge Tube for Lightning Protection 75V -3600V Gdt

















 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier